Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Radiother Oncol ; 193: 110143, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38341098

ABSTRACT

INTRODUCTION: Neurocognitive impairment from inadvertent brain irradiation is common following intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC). This study aimed to determine the prevalence, pattern, and radiation dose-toxicity relationship of this late complication. MATERIALS AND METHODS: We undertook a cross-sectional study of 190 post-IMRT NPC survivors. Neurocognitive function was screened using the Montreal Cognitive Assessment-Hong Kong (HK-MoCA). Detailed assessments of eight distinct neurocognitive domains were conducted: intellectual capacity (WAIS-IV), attention span (Digit Span and Visual Spatial Span), visual memory (Visual Reproduction Span), verbal memory (Auditory Verbal Learning Test), processing speed (Color Trail Test), executive function (Stroop Test), motor dexterity (Grooved Pegboard Test) and language ability (Verbal Fluency Test). The mean percentiles and Z-scores were compared with normative population data. Associations between radiation dose and brain substructures were explored using multivariable logistic regression. RESULTS: The median post-IMRT interval was 7.0 years. The prevalence of impaired HK-MoCA was 25.3 % (48/190). Among the participants, 151 (79.4 %) exhibited impairments in at least one neurocognitive domain. The predominantly impaired domains included verbal memory (short-term: mean Z-score, -0.56, p < 0.001; long-term: mean Z-score, -0.70, p < 0.001), processing speed (basic: mean Z-score, -1.04, p < 0.001; advanced: mean Z-score, -0.38, p < 0.001), executive function (mean Z-score, -1.90, p < 0.001), and motor dexterity (dominant hand: mean Z-score, -0.97, p < 0.001). Radiation dose to the whole brain, hippocampus, and temporal lobe was associated with impairments in executive function, verbal memory, processing speed, and motor dexterity. CONCLUSIONS: Neurocognitive impairment is prevalent and profound in post-IMRT NPC survivors. Cognitive assessment and rehabilitation should be considered part of survivorship care.


Subject(s)
Nasopharyngeal Neoplasms , Radiation Injuries , Radiotherapy, Intensity-Modulated , Humans , Nasopharyngeal Neoplasms/radiotherapy , Nasopharyngeal Carcinoma/radiotherapy , Radiotherapy, Intensity-Modulated/adverse effects , Cross-Sectional Studies , Executive Function , Radiation Injuries/epidemiology , Radiation Injuries/etiology , Neuropsychological Tests
2.
Radiother Oncol ; 177: 105-110, 2022 12.
Article in English | MEDLINE | ID: mdl-36336109

ABSTRACT

BACKGROUND: Post-radiation primary hypothyroidism is a common late complication in head and neck cancer (HNC) survivors. No radiation dose-volume constraint of the thyroid gland has been externally validated for predicting long-term thyroid function outcomes. MATERIALS AND METHODS: This external validation study evaluated the diagnostic properties of 22 radiation dose-volume constraints of the thyroid gland proposed in the literature. Radiation dosimetric data from 488 HNC patients who underwent neck irradiation from January 2013 to December 2015 at two tertiary oncology centers were reviewed. The diagnostic metrics of candidate constraints were computed by inverse probability of censoring weighting and compared using time-dependent receiver operating characteristic (ROC) curves with death designated as a competing event. Multivariable regression analyses were performed using the Fine-Gray sub-distribution hazard model. RESULTS: Over a median follow-up period of 6.8 years, 205 (42.0 %) patients developed post-radiation primary hypothyroidism. The thyroid volume spared from 60 Gy (VS60) had the largest area under ROC curve of 0.698 at 5 years after radiotherapy. Of all evaluated constraints, VS60 at a cutoff value of 10 cc had the highest F-score of 0.53. The 5-year hypothyroidism risks of patients with thyroid VS60 ≥ 10 cc and < 10 cc were 14.7 % and 38.2 %, respectively (p < 0.001). The adjusted sub-hazard ratio for post-radiation primary hypothyroidism for VS60 < 10 cc was 1.87 (95 % confidence interval, 1.22-2.87; p < 0.001). CONCLUSION: Thyroid VS60 is the best radiation dose-volume parameter to predict the long-term risk of primary hypothyroidism in patients with HNC who underwent neck irradiation. VS60 ≥ 10 cc is a robust constraint that limits the 5-year primary hypothyroidism risk to less than 15 % and should be routinely employed during radiotherapy optimization.


Subject(s)
Head and Neck Neoplasms , Hypothyroidism , Radiation Injuries , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy, Intensity-Modulated/adverse effects , Radiation Injuries/epidemiology , Radiation Injuries/etiology , Head and Neck Neoplasms/complications , Hypothyroidism/etiology , Radiotherapy Dosage
3.
Clin Transl Radiat Oncol ; 33: 83-92, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35128087

ABSTRACT

BACKGROUND AND PURPOSE: This systematic review aims to identify radiation dose-volume predictors of primary hypothyroidism after radiotherapy in patients with head and neck cancer (HNC). MATERIALS AND METHODS: We performed a systematic literature search of Medline, EMBASE and Web of Science from database inception to July 1, 2021 for articles that discuss radiation dose-volume predictors of post-radiation primary hypothyroidism in patients with HNC. Data on the incidence, clinical risk factors and radiation dose-volume parameters were extracted. A meta-analysis was performed using the random-effects model to estimate the pooled odds ratio (OR) of thyroid volume as a predictor of the risk of post-radiation hypothyroidism, adjusted for thyroid radiation dosimetry. RESULTS: Our search identified 29 observational studies involving 4,530 patients. With median follow-up durations ranging from 1.0 to 5.3 years, the average crude incidence of post-radiation primary hypothyroidism was 41.4 % (range, 10 %-57 %). Multiple radiation dose-volume parameters were associated with post-radiation primary hypothyroidism, including the thyroid mean dose (Dmean), minimum dose, V25, V30, V35, V45, V50, V30-60, VS45 and VS60. Thyroid Dmean and V50 were the most frequently proposed dosimetric predictors. The pooled adjusted OR of thyroid volume on the risk of post-radiation primary hypothyroidism was 0.89 (95 % confidence interval, 0.85-0.93; p < 0.001) per 1 cc increment. CONCLUSION: Post-radiation primary hypothyroidism is a common late complication after radiotherapy for HNC. Minimizing inadvertent exposure of the thyroid gland to radiation is crucial to prevent this late complication. Radiation dose-volume constraints individualized for thyroid volume should be considered in HNC radiotherapy planning.

4.
Phys Med ; 91: 1-12, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34678686

ABSTRACT

PURPOSE: To investigate the dosimetric accuracy of synthetic computed tomography (sCT) images generated by a clinically-ready voxel-based MRI simulation package, and to develop a simple and feasible method to improve the accuracy. METHODS: 20 patients with brain tumor were selected to undergo CT and MRI simulation. sCT images were generated by a clinical MRI simulation package. The discrepancy between planning CT and sCT in CT number and body contour were evaluated. To resolve the discrepancies, an sCT specific CT-relative electron density (RED) calibration curve was used, and a layer of pseudo-skin was created on the sCT. The dosimetric impact of these discrepancies, and the improvement brought about by the modifications, were evaluated by a planning study. Volumetric modulated arc therapy (VMAT) treatment plans for each patient were created and optimized on the planning CT, which were then transferred to the original sCT and the modified-sCT for dose re-calculation. Dosimetric comparisons and gamma analysis between the calculated doses in different images were performed. RESULTS: The average gamma passing rate with 1%/1 mm criteria was only 70.8% for the comparison of dose distribution between planning CT and original sCT. The mean dose difference between the planning CT and the original sCT were -1.2% for PTV D95 and -1.7% for PTV Dmax, while the mean dose difference was within 0.7 Gy for all relevant OARs. After applying the modifications on the sCT, the average gamma passing rate was increased to 92.2%. Mean dose difference in PTV D95 and Dmax were reduced to -0.1% and -0.3% respectively. The mean dose difference was within 0.2 Gy for all OAR structures and no statistically significant difference were found. CONCLUSIONS: The modified-sCT demonstrated improved dosimetric agreement with the planning CT. These results indicated the overall dosimetric accuracy and practicality of this improved MR-based treatment planning method.


Subject(s)
Brain Neoplasms , Radiotherapy, Intensity-Modulated , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/radiotherapy , Humans , Magnetic Resonance Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
5.
Med Dosim ; 46(1): 39-44, 2021.
Article in English | MEDLINE | ID: mdl-32768273

ABSTRACT

PURPOSE: Radiation-induced hypoglossal nerve palsy is an infrequent but debilitating late complication after definitive radiotherapy for head and neck cancers. D1cc < 74 Gy (equivalent dose in 2 Gy fractions, EQD2) has been proposed as a potential dose constraint that limits 8-year palsy risk to < 5%. This study sets to perform detailed dosimetric assessments on the applicability of this novel dose constraint in advanced nasopharyngeal carcinoma (NPC). MATERIALS AND METHODS: This is a retrospective single-institution dosimetry study. NPC radiotherapy plans were identified from an institutional database, with an aim to select 10 eligible cases. Bilateral hypoglossal nerves were retrospectively contoured following a standard atlas. Cases with either one, or both, hypoglossal nerves D1cc exceeded 74 Gy EQD2 were included. Dosimetry of hypoglossal nerves, planning target volumes (PTV) and normal structures before and after application of the new hypoglossal nerve constraint were compared and analyzed. RESULTS: Ten NPC cases were replanned. All hypoglossal nerve contours overlapped with high-dose PTV, predominantly at regions of gross nodal diseases. D1cc in 15 out of 20 hypoglossal nerves exceeded 74G y EQD2 at initial plans. All nerves fulfilled the pre-specified constraint of 74Gy EQD2 after re-plan. Median hypoglossal nerve D1cc reduced from 74.8Gy (range, 74.1 to 77.4Gy) to 73.5Gy (range, 72.4 to 74.0Gy) (p < 0.001), corresponded to a projected reduction in 8-year palsy risk from 5%-14% to 3%-5%. PTV V100 was maintained above 95% in all cases. Dose increments in near-maximum (D2) and decrements in near-minimum (D98) were < 1 Gy. Safety dosimetric parameters of standard head and neck organs-at-risk showed no significant changes. CONCLUSIONS: Hypoglossal nerve D1cc < 74 Gy EQD2 is a dosimetrically feasible constraint in definitive radiotherapy for NPC. Tumor target coverage and normal organ dosimetry were not compromised with its usage. Its routine application should be considered in definitive radiotherapy for head and neck cancers.


Subject(s)
Nasopharyngeal Neoplasms , Radiotherapy, Intensity-Modulated , Feasibility Studies , Humans , Hypoglossal Nerve , Nasopharyngeal Carcinoma/radiotherapy , Nasopharyngeal Neoplasms/radiotherapy , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated/adverse effects , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...